Abstract :
In this paper we study the compression of the human retina image by the method of Douglas Peucker (DP), and we used fractal interpolation (IFS) and linear interpolation to decompress the coded image. The results show that the method of Douglas-Peucker reduces the image size up to about 92 to 96 %, a rate that is important. The PSNR value obtained by the fractal interpolation is between 27.171 dB and 36.9028 dB, cons, the PSNR value is obtained from linear interpolation 27.659 dB. We see that the PSNR value of fractal interpolation is better than the PSNR value of linear interpolation. We conclude with a fractal interpolation can have a better quality picture, by cons, which is obtained with the interpolation image of lower quality.
Keywords :
data compression; feature extraction; image coding; image reconstruction; interpolation; medical image processing; DP method; Douglas Peucker method; IFS; PSNR; characteristic point extraction; coded image decompression; fractal interpolation; human retina image compression; linear interpolation; retinal vasculature reconstruction; Fractals; Image coding; Interpolation; PSNR; Retina; Shape; Skeleton; Douglas-Peuker algorithm; fractal interpolation; linear interpolation; retinal blood vessel image;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sciences of Electronics, Technologies of Information and Telecommunications (SETIT), 2012 6th International Conference on
Conference_Location :
Sousse
Print_ISBN :
978-1-4673-1657-6
Type :
conf
DOI :
10.1109/SETIT.2012.6481953
Filename :
6481953
Link To Document :
بازگشت