  • Abstract
    High quality images have many uses, such as the testing of image processing algorithms and serving as templates for registration in image guided surgery. This work describes the creation of four high quality images or "appearance models", for 1. myocardium, 2. right atrium and ventricle, 3. left atrium and aorta, and 4. epicardial surface. The appearance models are created by registering and averaging together a series of high-resolution MR images of the same volunteer. These are then corrected to represent the average shape as determined from MR data of ten other volunteers. Thus, we show how single volunteer imaging can be combined with image registration to generate average-shape appearance models with high resolution and signal-to-noise ratio. Our final data consist of four 3D average shape appearance models (each depicting one of the sub-heart components) with 1.5 times 1.5 times 1.5 mm voxels and a signal-to-noise ratio increase of 6.6 versus raw data
  • Keywords
    biomedical MRI; cardiology; image registration; image resolution; medical image processing; physiological models; 3D average shape appearance models; MR images; heart subcomponents; image guided surgery; image processing; image registration; Biomedical imaging; Heart; High-resolution imaging; Image processing; Image registration; Myocardium; Shape; Signal to noise ratio; Surgery; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
  • Conference_Location
    Shanghai
  • Print_ISBN
    0-7803-8741-4
  • Type

    conf

  • DOI
    10.1109/IEMBS.2005.1616741
  • Filename
    1616741