DocumentCode
1610241
Title
The Inverse Problem of a Passive Multiband Microwave Intracranial Imaging Method
Author
Karanasiou, I.S. ; Uzunoglu, N.K.
Author_Institution
Nat. Tech. Univ. of Athens
fYear
2006
Firstpage
1642
Lastpage
1645
Abstract
A novel microwave radiometry imaging system (MiRaIS) has been developed and experimentally tested for feasible brain activation "remote" imaging via contactless measurements. The technique implemented, is focused microwave radiometry with the use of an ellipsoidal conductive wall cavity for focusing and a sensitive radiometric receiver for the detection of the brain conductivity and temperature variation. All system attributes in terms of spatial resolution and detection depth have been theoretically calculated. Phantom experimentation as well as human tests using single frequency receivers, have shown promising outcome concerning the potential clinical value of the proposed system, which seems to be able to pick-up brain activation, possibly caused by cortex conductivity changes. Following this research, a four-frequency radiometric receiver with a broadband antenna operating within the range 1.3-3.1 GHz has been recently developed. In the present paper, a method for retrieving the conductivity variation profile detected in the above mentioned frequencies is discussed. The inverse problem solution is in detail addressed and indicative measurements are used for the validation of the solution in question. The latter represents the estimation of the conductivity variation of cortical areas, corresponding to the detection depth and spatial resolution predicted by the forward problem solution
Keywords
bioelectric phenomena; biothermics; brain; inverse problems; microwave imaging; phantoms; radiometry; 1.3 to 3.1 GHz; brain activation remote imaging; brain conductivity; cortex conductivity changes; detection depth; ellipsoidal conductive wall cavity; focused microwave radiometry; forward problem solution; four-frequency radiometric receiver; inverse problem; microwave radiometry imaging system; passive multiband microwave intracranial imaging method; phantom; sensitive radiometric receiver; single frequency receivers; spatial resolution; temperature variation; Broadband antennas; Conductivity; Focusing; Frequency; Inverse problems; Microwave imaging; Microwave radiometry; Microwave theory and techniques; Spatial resolution; System testing; Microwave multiband radiometry; brain imaging; inverse problem;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location
Shanghai
Print_ISBN
0-7803-8741-4
Type
conf
DOI
10.1109/IEMBS.2005.1616754
Filename
1616754
Link To Document