• DocumentCode
    1610288
  • Title

    An improved calorimeter for measuring the core loss of magnetic materials

  • Author

    Linkous, Ralph ; Kelley, Arthur W. ; Armstrong, K.C.

  • Author_Institution
    Dept. of Electr. Eng., North Carolina State Univ., Raleigh, NC, USA
  • Volume
    2
  • fYear
    2000
  • fDate
    6/22/1905 12:00:00 AM
  • Firstpage
    633
  • Abstract
    Accurate measurements of core loss for distributed-air-gap magnetic materials have traditionally been very difficult to obtain. Wattmeter measurements are affected by very small phase and time-delay measurement errors, while traditional calorimeters measure the sum of excitation winding loss and core loss. This paper presents an improved calorimeter which excludes winding loss and measures core loss alone
  • Keywords
    air gaps; calorimeters; loss measurement; magnetic cores; magnetic leakage; magnetic materials; calorimeter; core loss measurement; distributed-air-gap magnetic materials; magnetic materials; time-delay measurement errors; very small phase measurement errors; wattmeter measurements; Copper; Core loss; Electric variables measurement; Loss measurement; Magnetic cores; Magnetic materials; Phase measurement; Power electronics; Testing; Wattmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference and Exposition, 2000. APEC 2000. Fifteenth Annual IEEE
  • Conference_Location
    New Orleans, LA
  • Print_ISBN
    0-7803-5864-3
  • Type

    conf

  • DOI
    10.1109/APEC.2000.822571
  • Filename
    822571