• DocumentCode
    1610618
  • Title

    A loosely winding transformer with series resonant converter

  • fYear
    2013
  • Firstpage
    395
  • Lastpage
    398
  • Abstract
    This paper focus on analysis, design and measurement results of the loosely winding contactless transformer using resonant converter. Next, the experimental set up is built to transfer power of 300W over the different gap variation (1mm-10mm) using series resonant converter. Compare to the traditional closely coupled transformer, the contactless transformer with separated primary and secondary winding is used. A loosely contactless transformer with a large air gap has small magnetizing inductance and large leakage inductance comparing with a closely conventional transformer.
  • Keywords
    inductive power transmission; resonant power convertors; transformers; contactless transformer; different gap variation; large leakage inductance; loosely winding transformer; magnetizing inductance; power 300 W; series resonant converter; Capacitors; Contacts; Inductance; Power transformer insulation; Resonant frequency; Switching frequency; Windings; Contactless power transfer; contactless transformer; resonant converter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Clean Energy and Technology (CEAT), 2013 IEEE Conference on
  • Conference_Location
    Lankgkawi
  • Print_ISBN
    978-1-4799-3237-5
  • Type

    conf

  • DOI
    10.1109/CEAT.2013.6775663
  • Filename