DocumentCode
1610618
Title
A loosely winding transformer with series resonant converter
fYear
2013
Firstpage
395
Lastpage
398
Abstract
This paper focus on analysis, design and measurement results of the loosely winding contactless transformer using resonant converter. Next, the experimental set up is built to transfer power of 300W over the different gap variation (1mm-10mm) using series resonant converter. Compare to the traditional closely coupled transformer, the contactless transformer with separated primary and secondary winding is used. A loosely contactless transformer with a large air gap has small magnetizing inductance and large leakage inductance comparing with a closely conventional transformer.
Keywords
inductive power transmission; resonant power convertors; transformers; contactless transformer; different gap variation; large leakage inductance; loosely winding transformer; magnetizing inductance; power 300 W; series resonant converter; Capacitors; Contacts; Inductance; Power transformer insulation; Resonant frequency; Switching frequency; Windings; Contactless power transfer; contactless transformer; resonant converter;
fLanguage
English
Publisher
ieee
Conference_Titel
Clean Energy and Technology (CEAT), 2013 IEEE Conference on
Conference_Location
Lankgkawi
Print_ISBN
978-1-4799-3237-5
Type
conf
DOI
10.1109/CEAT.2013.6775663