Abstract :
The paper outlines shaking table tests and their results for an active seismic response control system that uses fuzzy optimal logic (FOL). The shaking table test results confirmed the validity of the vibration control effect of this seismic response control system. The results of this study lead to two conclusions, that the effectiveness of this FOL control system can be increased by modifying the membership function, and that the results of seismic response control tests can be qualitatively evaluated by two simulation methods
Keywords :
building; fuzzy control; fuzzy logic; optimal control; seismology; vibration control; FOL control system; active seismic response control system; building structure; fuzzy optimal logic; membership function; seismic response control system; seismic response control tests; shaking table tests; simulation methods; vibration control effect; Buildings; Control system synthesis; Control systems; Fuzzy control; Fuzzy logic; Fuzzy systems; Logic testing; Optimal control; System testing; Vibration control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Uncertainty Modeling and Analysis, 1995, and Annual Conference of the North American Fuzzy Information Processing Society. Proceedings of ISUMA - NAFIPS '95., Third International Symposium on
Conference_Location :
College Park, MD
Print_ISBN :
0-8186-7126-2
Type :
conf
DOI :
10.1109/ISUMA.1995.527667
Filename :
527667
Link To Document :
بازگشت