DocumentCode :
1613345
Title :
Fault detection on multilevel power converter based on mass center of the voltage pattern
Author :
Fernao Pires, V. ; Foito, Daniel ; Sousa, Duarte M. ; Martins, J.F.
Author_Institution :
Escola Super. Tecnol. Setubal, Inst. Politec. Setubal, Setubal, Portugal
fYear :
2013
Firstpage :
576
Lastpage :
581
Abstract :
Multilevel power converters are now used in many applications. This type of power converter is characterized by the increased likelihood of a switch failure due to the high number of switches. However, this also allows reconfiguring the power converter in order to work even under internal fault condition. This paper introduces a new approach to detected and identify a faulty switch. The proposed method uses the power converter output voltages and is based on mass center of the voltages patterns. This approach is illustrated on a five-level cascaded H-bridge inverter. From the obtained simulation and experimental results it is possible to confirm the applicability of the proposed approach.
Keywords :
fault diagnosis; invertors; faulty switch detection; faulty switch identification; five-level cascaded H-bridge inverter; multilevel power converter; voltage pattern mass center; Conferences; Decision support systems; Power engineering; Multilevel voltage source inverter; cascaded H-bridge; fault diagnosis; mass center; voltage pattern;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Engineering, Energy and Electrical Drives (POWERENG), 2013 Fourth International Conference on
Conference_Location :
Istanbul
ISSN :
2155-5516
Type :
conf
DOI :
10.1109/PowerEng.2013.6635672
Filename :
6635672
Link To Document :