• DocumentCode
    1613661
  • Title

    Shaft voltages caused by alternating flux encircling the shaft

  • Author

    Pratt, J.W.

  • Author_Institution
    Brush Electrical Machines Ltd., UK
  • fYear
    1995
  • Firstpage
    198
  • Lastpage
    202
  • Abstract
    If a voltmeter is connected across the two ends of the shaft of a rotating electrical machine, a small voltage can normally be detected. In many cases this voltage is too small to cause problems, but if it reaches a level at which significant current starts to flow through bearings or other components attached to the shaft, then precautions such as insulating the bearings will be required. A brief review of the various mechanisms for the generation of shaft voltage is given, and one of these, involving a nonuniform air gap and alternating flux linkages with the shaft, is considered in detail for a particular machine. Simplified theory is presented together with a calculation procedure that is tested against measured results
  • Keywords
    air gaps; electric machines; machine theory; magnetic flux; alternating flux linkages; bearings insulation; magnetically unbalanced machine; nonuniform air gap; rotating electrical machine; shaft voltages generation; voltmeter;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1995. Seventh International Conference on (Conf. Publ. No. 412)
  • Conference_Location
    Durham
  • Print_ISBN
    0-85296-648-2
  • Type

    conf

  • DOI
    10.1049/cp:19950862
  • Filename
    497723