Abstract :
This paper presents experimental results concerning the negative sequence impedance Z/sub n/ of induction motors with different rotor slot constructions. Z/sub n/ is used as a fault index for shorted turns in stator windings, or can be used to distinguish negative sequence current due to unbalanced supply voltage from negative sequence current due to stator shorts. Although Z/sub n/ is largely independent of speed changes, experiments show that it can vary strongly with motor loading. Results presented show that, depending on rotor slot type, negative sequence reactance can change by as much as 10% to 50%, especially in motors with closed rotor slots.
Keywords :
electric current measurement; electric impedance; electric reactance measurement; induction motors; machine testing; machine theory; rotors; short-circuit currents; stators; closed rotor slot effect; fault index; induction motors; negative sequence current; negative sequence impedance; rotor slot constructions; rotor slot type; stator winding shorted turns; unbalanced supply voltage; Circuit faults; Condition monitoring; Equivalent circuits; Impedance measurement; Induction motors; Postal services; Rotors; Stator windings; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 2001. Thirty-Sixth IAS Annual Meeting. Conference Record of the 2001 IEEE
Conference_Location :
Chicago, IL, USA
ISSN :
0197-2618
Print_ISBN :
0-7803-7114-3
Type :
conf
DOI :
10.1109/IAS.2001.955529
Filename :
955529
Link To Document :
بازگشت