DocumentCode
1615306
Title
Consideration of interference between parallel connected class D amplifiers operated at different switching frequencies
Author
Ishikawa, Yozo ; Yamamoto, Ryo ; Uchiyama, Hiroyuki ; Wei, Xiuqin ; Sekiya, Hiroo ; Suetsugu, Tadashi
Author_Institution
Dept. of Electron. Eng. & Comput. Sci., Fukuoka Univ., Fukuoka, Japan
fYear
2013
Firstpage
1034
Lastpage
1037
Abstract
Multi frequency coupling is widely used in plasma processing technology in order to improve controllability of plasma chamber. This paper researches about influence of multi-frequency operation of parallel connected high efficiency switching power amplifier, class D amplifiers. In the analysis, it is seen that variation in dc supply voltage of one amplifier leg does not influence to output waveform of another amplifier leg. However, parallel connection of two amplifiers influences output power of both amplifiers due to change in impedance of output filter. A decoupling filter is proposed to the output of higher frequency amplifier to reduce the coupling. It is shown that decoupling filter successfully improved coupling between amplifiers.
Keywords
HF amplifiers; filters; power amplifiers; amplifier leg; dc supply voltage variation; decoupling filter; frequency amplifier; multifrequency coupling; parallel connected class D amplifiers; parallel connected high efficiency switching power amplifier; plasma chamber; plasma processing technology; switching frequency; Couplings; Integrated circuit modeling; Plasmas; Power amplifiers; Power engineering; Power generation; Radio frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering, Energy and Electrical Drives (POWERENG), 2013 Fourth International Conference on
Conference_Location
Istanbul
ISSN
2155-5516
Type
conf
DOI
10.1109/PowerEng.2013.6635753
Filename
6635753
Link To Document