Abstract :
The influence of a PWM waveform on motor insulation lifetime is studied. In the first stage of the work, tests are performed on a motor, reproducing its working conditions: by means of suitable taps, the turn-to-ground voltage existing on the turns of the first two coils as better specified below are acquired. Afterwards ageing tests are performed on parts of stator windings applying test voltages whose parameters have been chosen on the basis of the previously described measurements
Keywords :
AC motors; insulation testing; life testing; machine insulation; machine testing; pulse width modulation; stators; PWM waveform; ageing tests; coils; electric motors; high frequency tests; high voltage tests; motor insulation lifetime; pulse width modulation; stator windings; taps; test voltages; turn-to-ground voltage; Coils; Electric motors; Employee welfare; Frequency; Insulation; Performance evaluation; Pulse width modulation; Stators; Testing; Voltage;