• DocumentCode
    1617159
  • Title

    Application of wavelet analysis to the plethysmogram for the evaluation of mental stress

  • Author

    Yashima, K. ; Sasaki, T. ; Kageyama, Y. ; Odagaki, M. ; Hosaka, H.

  • Author_Institution
    Graduate Sch. of Sci. & Eng., Tokyo Denki Univ., Saitama
  • fYear
    2006
  • Firstpage
    2781
  • Lastpage
    2784
  • Abstract
    The present study proposes a new stress evaluation technique using the photoplethysmogram (PTG). Heart rate variability (HRV) is often used to evaluate mental stress. HRV can be measured from an electrocardiogram (ECG). The frequency variability of HRV and mental stress response are related. PTG also indicates changes in emotional response. PTG can easily be measured without body surface electrodes. This method is less invasive than ECG measurement. We attempt herein to evaluate mental stress by wavelet analysis of the PTG. PTG was measured in the resting and mental stress states, and wavelet transformed PTGs were compared. In nine out of ten subjects, the wavelet result for PTG revealed a decrease in the frequency band
  • Keywords
    bio-optics; neurophysiology; plethysmography; wavelet transforms; ECG; HRV; PTG; electrocardiogram; emotional response; heart rate variability; mental stress; photoplethysmgram; plethysmogram; wavelet analysis; wavelet transform; Arithmetic; Continuous wavelet transforms; Engineering in medicine and biology; Frequency dependence; Human factors; Sampling methods; Stress measurement; Time frequency analysis; Wavelet analysis; Wavelet transforms; mental stress; photoplethysmogram; wavelet;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
  • Conference_Location
    Shanghai
  • Print_ISBN
    0-7803-8741-4
  • Type

    conf

  • DOI
    10.1109/IEMBS.2005.1617049
  • Filename
    1617049