• DocumentCode
    1618576
  • Title

    Fiber-optic thermometer for high temperature measurement

  • Author

    Aizawa, Hiroaki ; Katsumata, Tooru ; Komuro, Shuji ; Morikawa, Takitaro ; Ishizawa, Hiroaki ; Toba, Eiji

  • Author_Institution
    Sensor Photonics Res. Center, Toyo Univ., Saitama
  • fYear
    2006
  • Firstpage
    1899
  • Lastpage
    1902
  • Abstract
    A fiber-optic fluorescence thermometer is a useful technique for temperature measurement in extraordinary conditions. However, high temperature measurement is hard for the fluorescence thermometer due to thermal quenching of fluorescence. To develop the wide range thermometer, a hybrid fiber-optic thermometer which combines the fluorescence thermometry and the thermal radiation thermometry has been fabricated using Cr ion doped phosphor crystal. In this paper, temperature dependence of fluorescent lifetime and blackbody radiation from Cr ion doped phosphor crystal is reported for wide range temperature measurement
  • Keywords
    chromium; fibre optic sensors; fluorescence; optical fibre fabrication; optical materials; phosphors; radiation quenching; spectral methods of temperature measurement; thermometers; yttrium compounds; YAG:Cr; YAl5O12:Cr; blackbody radiation; chromium ion doped phosphor crystal; fiber-optic fluorescence thermometer fabrication; fluorescent lifetime; high-temperature measurement; thermal quenching; thermal radiation thermometry; Chromium; Fluorescence; Optical fiber devices; Optical fiber sensors; Optical fibers; Phosphors; Temperature dependence; Temperature measurement; Temperature sensors; Thermal sensors; Blackbody radiation; Fluorescence; High temperature; Optical fiber; Thermometer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE-ICASE, 2006. International Joint Conference
  • Conference_Location
    Busan
  • Print_ISBN
    89-950038-4-7
  • Electronic_ISBN
    89-950038-5-5
  • Type

    conf

  • DOI
    10.1109/SICE.2006.315280
  • Filename
    4108995