DocumentCode
1619132
Title
B-dot Detector Signal Recording at the DARHT II Accelerator
Author
Johnson, Jeffrey B. ; Ekdahl, Carl A. ; Broste, William B.
Author_Institution
Los Alamos Nat. Lab., Los Alamos
fYear
2007
Firstpage
371
Lastpage
371
Abstract
Summary form only given. Diagnostic detectors such as B-dot and E-dot probes have been used in pulse power and accelerator applications for decades. The DARHT II Accelerator utilizes arrays of B-dot detectors as a means to determine beam current and position. Unique problems arise when using digital recording to capture these signal waveforms. Bit error and baseline reference stability in the recording devices limits the accuracy of the recorded waveform when dealing with fast rise time signals that have relatively long pulse widths. The reasons for methods used to record the B-dot data for the 2 microsecond duration beam current at DARHT II are detailed in this paper.
Keywords
linear accelerators; particle beam diagnostics; B-DOT detector signal recording; DARHT II accelerator; beam current; beam position; Acceleration; Detectors; Digital recording; Laboratories; Particle beams; Probes; Sensor arrays; Signal detection; Stability; USA Councils;
fLanguage
English
Publisher
ieee
Conference_Titel
Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
Conference_Location
Albuquerque, NM
ISSN
0730-9244
Print_ISBN
978-1-4244-0915-0
Type
conf
DOI
10.1109/PPPS.2007.4345677
Filename
4345677
Link To Document