• DocumentCode
    1620566
  • Title

    A field-circuit approach to the design oriented evaluation of the no-load voltage harmonics of salient pole synchronous generators

  • Author

    Di Gerlando, Antonino ; Perini, R. ; Vistoli, I.

  • Author_Institution
    Dipartimento di Elettrotecnica, Politecnico di Milano, Italy
  • fYear
    1995
  • Firstpage
    390
  • Lastpage
    394
  • Abstract
    The standards establish definite limits on the waveform distortion of the no-load voltage of the salient-pole synchronous generators, by means of the total harmonic distortion (THD) and the telephonic harmonic factor (THF): the constructional measures suited to reduce this distortion are numerous, and it is important to evaluate their effects during the design. A method for the calculation of the no-load voltage distortion, taking into account the presence of the teeth, the winding and pole shoe characteristics, the saturation in all the magnetic branches and the skewing between stator and rotor is described and discussed. An example of application is shown and the effect of some constructional measures is analysed
  • Keywords
    harmonic distortion; machine theory; magnetic flux; rotors; stators; synchronous generators; air gap; design oriented evaluation; field-circuit approach; flux linkage; magnetic branches; no-load voltage distortion; no-load voltage harmonics; permeance evaluation; pole shoe characteristics; rotor; salient pole synchronous generators; skewing; stator; teeth; telephonic harmonic factor; total harmonic distortion; waveform distortion; winding;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1995. Seventh International Conference on (Conf. Publ. No. 412)
  • Conference_Location
    Durham
  • Print_ISBN
    0-85296-648-2
  • Type

    conf

  • DOI
    10.1049/cp:19950900
  • Filename
    497762