In this paper, we introduce a charge integrator as a read-out system for piezoelectric cantilever sensors. The charge integrator is used to monitor the surface charge induced by piezoelectric materials as a function of mechanical stress. This technique improves the response of piezoelectric cantilever sensors in low frequency measurements which makes them suitable for chemical and biological detection. Furthermore, it is capable of real-time, portable and all electrical detection. The detection of alkanethiols on the Au-coated piezoelectric cantilevers is demonstrated to verify the concept.
Keywords :
cantilevers; piezoelectric transducers; stress analysis; charge integrator; mechanical stress; piezoelectric cantilever sensors; read-out system; surface stress induced deflections; Biosensors; Capacitors; Chemical and biological sensors; Mechanical sensors; Monitoring; Piezoelectric films; Piezoelectric materials; Sensor systems; Stress; Voltage; Alkanethiol; Charge integrator; Piezoelectric cantilever; Self-assembled monolayer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Control, Automation and Systems, 2008. ICCAS 2008. International Conference on
Conference_Location :
Seoul
Print_ISBN :
978-89-950038-9-3
Electronic_ISBN :
978-89-93215-01-4
Type :
conf
DOI :
10.1109/ICCAS.2008.4694629
Filename :
4694629
Link To Document :
بازگشت