Application of pressure differentiator using isothermal chamber to isolation table
Author
Kato, T. ; Kawashima, K. ; Yanagisawa, M. ; Kagawa, T.
Author_Institution
Tokyo Metropolitan Coll. of Technol., Shinagawa, Japan
Volume
1
fYear
2004
Firstpage
845
Abstract
In this paper, the mechanism of a pressure differentiator, applying the principle of an isothermal chamber is explained. The pressure differentiator is then applied to the pressure control of an isolation table, as constituting minor feedback, in order to compensate the non-linearity of a servo valve and realize an isolation table with higher gain and lower energy consumption.
Keywords
cascade control; feedback; pressure control; vibration isolation; D-PI pressure control system; cascade control; energy consumption; feedback; isolation table pressure control; isothermal chamber; pressure differentiator; servo valve;