• DocumentCode
    1622878
  • Title

    A sophisticated maximum capacity analysis for large turbine generators considering limitation of temperature

  • Author

    Ide, K. ; Hattori, K. ; Takahashi, K. ; Kobashi, K. ; Watanabe, T.

  • Author_Institution
    Res. Lab., Hitachi Ltd., Ibaraki, Japan
  • Volume
    2
  • fYear
    2003
  • Firstpage
    948
  • Abstract
    In this paper, the authors propose a sophisticated analysis method to determine possible maximum generator capacity and to evaluate the generator´s potential ability. The method is developed to survey generator design parameters on a large scale efficiently and objectively. The possible maximum generator capacity acquired by the proposed method satisfies the specifications of short circuit ratio, power factor and temperature limitations of armature and field windings. Armature voltage, armature current and field current are optimized simultaneously. An example adopting the proposed method is also shown in this paper. The results indicate the sensitivities of the calculated possible maximum generator capacity and the calculated loss for various development factors. The effectiveness of this method in the R&D phase is clarified by the example.
  • Keywords
    cooling; machine theory; machine windings; thermal analysis; turbogenerators; R&D; armature current; armature voltage; field current; fleld windings; generator design parameters; large turbine generators; maximum capacity analysis; power factor; short circuit ratio; temperature limitation; temperature limitations; Coolants; Laboratories; Large-scale systems; Power generation; Research and development; Rotors; Stators; Temperature distribution; Turbines; Ventilation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International
  • Print_ISBN
    0-7803-7817-2
  • Type

    conf

  • DOI
    10.1109/IEMDC.2003.1210349
  • Filename
    1210349