Title :
High-sensitivity measurements of return loss by self-heterodyne in a laser diode
Author :
Donati, Silvano ; Sorel, Marc
Author_Institution :
Dipt. di Elettronica, Pavia Univ., Italy
Abstract :
Summary form only given. Return loss measurements in excess of 60 dB require high-sensitivity detectors and special care to avoid spurious contributions from the optics. We present a new method with an unprecedented sensitivity yet easy to implement, using a self-heterodyne sensing mechanism. Single-mode laser power is launched into the pigtail of a PZT phase modulator and gets into the device under test (DUT) through an angled joint. Light coupled back into the laser cavity generates a modulation of laser power, that can be picked by a photodetector placed on the rear mirror of the laser
Keywords :
demodulation; laser mirrors; measurement by laser beam; optical fibre losses; optical fibre testing; optical loss measurement; optical modulation; sensitivity; PZT phase modulator; angled joint; device under test; high-sensitivity detectors; high-sensitivity measurements; laser cavity; laser diode; laser power modulation; photodetector; rear mirror; return loss measurements; return optical loss measurement; self-heterodyne; sensing mechanism; single-mode laser power; spurious contributions; unprecedented sensitivity; Loss measurement; Optical coupling; Optical losses; Optical modulation; Optical sensors; Phase modulation; Photodetectors; Power generation; Power lasers; Testing;
Conference_Titel :
Optical Fiber Communication. OFC 97., Conference on
Conference_Location :
Dallas, TX
Print_ISBN :
1-55752-480-7
DOI :
10.1109/OFC.1997.719782