DocumentCode :
1623420
Title :
Back-to-back tests of a high-speed generator
Author :
Aglén, O.
Author_Institution :
Dept. of Electr. Eng., R. Inst. of Technol., Stockholm, Sweden
Volume :
2
fYear :
2003
Firstpage :
1084
Abstract :
The machine under study is a permanent magnet synchronous generator intended for operation at high speeds together with a micro-turbine in a combined heat and power (CHP) unit. Target power is 110 kW at 70000 rpm. The study is both theoretical and experimental since it includes calculation of loss distribution and thermal analysis together with calorimetric measurements of losses and temperature measurements. In this paper the experimental part of the work is described. The theoretical part is covered in an accompanying paper.
Keywords :
calorimetry; cogeneration; gas turbines; loss measurement; permanent magnet generators; synchronous generators; temperature measurement; thermal analysis; 110 kW; calorimetric measurements; combined heat and power unit; loss distribution; losses; micro-turbine; permanent magnet synchronous generator; temperature measurements; thermal analysis; Cogeneration; Costs; Out of order; Permanent magnets; Power generation; Rotors; Shafts; Stator cores; Testing; Turbines;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International
Print_ISBN :
0-7803-7817-2
Type :
conf
DOI :
10.1109/IEMDC.2003.1210370
Filename :
1210370
Link To Document :
بازگشت