Title :
Density Measurements in the Ablation Plasma of Tungsten Wire Array Z-Pinches
Author :
Douglass, J.D. ; Pikuz, S.A. ; Shelkovenko, T.A. ; Bell, K.S. ; Knapp, P.F. ; McBride, R.D. ; Hammer, D.A.
Author_Institution :
Cornell Univ. Ithaca, Ithaca
Abstract :
Summary form only given. X-pinch radiography has been used routinely at Cornell for more than 10 years to produce high quality X-ray images with excellent spatial and temporal resolution. This imaging technique is presently being used on the COBRA accelerator at Cornell University to study the ablation stage of wire-array z-pinches. Two of four return-current posts in the wire-array load region are replaced by Mo x-pinches. They are approximately 43 mm from the axis of the z-pinch. The experimental arrangement used here is very similar to the set-up that has been used at the Angara-5-1 facility near Moscow and also on MAGPIK at Imperial College in London. Typically, two x-pinches are used to image one wire in an eight-wire z-pinch from different angles. Images are obtained using Kodak EBioMAX MS and Technical Pan film. These films are typically placed 375 mm from the z-pinch axis yielding a magnification of about 9:1. The resulting X-ray images have sub-nanosecond temporal resolution because of the extremely short x pinch X-ray pulse duration and about 4 mum spatial resolution. Titanium filters are used to shield the films from visible light and transmit radiation in the spectral range 3-5 keV. Strong collimation is used to prevent radiation from the wire array z-pinch from exposing the films. Tungsten step wedges (step attenuators), which have steps ranging from 0.015-1.10 mum thick, placed on the Ti filters enable us to make density measurements of the ablation plasmas near the dense wire-cores. These density measurements are the main focus of this presentation.
Keywords :
Z pinch; plasma X-ray sources; plasma density; plasma diagnostics; tungsten; Angara-5-1 facility; COBRA accelerator; Cornell University; Kodak EBioMAX MS and Technical Pan film; MAGPIK; X-pinch radiography; X-ray imaging; ablation plasma; electron volt energy 3 keV to 5 keV; short X pinch X-ray pulse; step attenuators; titanium filter; tungsten step wedges; tungsten wire array Z-pinch; Density measurement; Filters; Image resolution; Plasma accelerators; Plasma density; Plasma measurements; Spatial resolution; Tungsten; Wire; X-ray imaging;
Conference_Titel :
Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0915-0
DOI :
10.1109/PPPS.2007.4345895