  • Abstract
    Simple enhancements to the nose-to-nose method of characterizing samplers are described. The technique is applied to a millimetre-wave sampler. These allow sampler magnitude and phase response to be measured to 150GHz and above. Excellent agreement is found with magnitude measurements made using conventional traceable power sensors.
  • Keywords
    millimetre wave measurement; signal sampling; 120 to 150 GHz; magnitude response; millimetre-wave sampler; nose-to-nose method; phase response; Convolution; Delay; Diodes; Frequency measurement; Instruments; Length measurement; Microwave technology; Microwave theory and techniques; Pulse measurements; Sampling methods;