DocumentCode
1624694
Title
Rapid millimetre-wave sampler response characterization to well beyond 120GHz using an improved nose-to-nose method
Author
Scott, J.B.
Author_Institution
Microwave Technol. Center, Agilent Technol., Santa Rosa, CA, USA
Volume
3
fYear
2003
Firstpage
1511
Abstract
Simple enhancements to the nose-to-nose method of characterizing samplers are described. The technique is applied to a millimetre-wave sampler. These allow sampler magnitude and phase response to be measured to 150GHz and above. Excellent agreement is found with magnitude measurements made using conventional traceable power sensors.
Keywords
millimetre wave measurement; signal sampling; 120 to 150 GHz; magnitude response; millimetre-wave sampler; nose-to-nose method; phase response; Convolution; Delay; Diodes; Frequency measurement; Instruments; Length measurement; Microwave technology; Microwave theory and techniques; Pulse measurements; Sampling methods;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Symposium Digest, 2003 IEEE MTT-S International
Conference_Location
Philadelphia, PA, USA
ISSN
0149-645X
Print_ISBN
0-7803-7695-1
Type
conf
DOI
10.1109/MWSYM.2003.1210423
Filename
1210423
Link To Document