• DocumentCode
    1624757
  • Title

    100 GHz through-line sampler system with sampling rates in excess of 10 Gsamples/second

  • Author

    Agoston, A. ; Pepper, S. ; Norton, R. ; Ebner, J. ; Schoen, K.

  • Author_Institution
    Picosecond Pulse Labs, Boulder, CO, USA
  • Volume
    3
  • fYear
    2003
  • Firstpage
    1519
  • Abstract
    A through-line electrical sampler with 100 GHz of bandwidth and sampling rates in excess of 10 Gsamples/s has been fabricated and characterized. The sampling aperture is estimated to be approximately 3 ps. The linear dynamic range is >2 Vpp. The performance of this sampling component enables significant advancements in high-speed test and measurement equipment and mm-wave Ultra-wideband (UWB) receivers.
  • Keywords
    signal sampling; 100 GHz; MM-wave UWB receiver; high-speed measurement equipment; linear dynamic range; sampling aperture; through-line electrical sampler; Apertures; Bandwidth; Optical pulse generation; Optical pulses; Oscilloscopes; Packaging; Radio frequency; Sampling methods; Schottky diodes; Semiconductor diodes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest, 2003 IEEE MTT-S International
  • Conference_Location
    Philadelphia, PA, USA
  • ISSN
    0149-645X
  • Print_ISBN
    0-7803-7695-1
  • Type

    conf

  • DOI
    10.1109/MWSYM.2003.1210425
  • Filename
    1210425