• DocumentCode
    1626879
  • Title

    Cygnus Performance in Subcritical Experiments

  • Author

    Smith, John R. ; Nelson, Daniel S. ; Ormond, Eugene C. ; Cordova, Steve R. ; Molina, Isidro ; Corrow, George D. ; Hansen, Mark D. ; Henderson, David J. ; Lutz, Stephen S. ; Mitton, Charles V.

  • Author_Institution
    Los Alamos Nat. Lab., Los Alamos
  • fYear
    2007
  • Firstpage
    685
  • Lastpage
    685
  • Abstract
    Summary form only given. The Cygnus Dial Beam Radiographic Facility consists of two identical radiographic sources with the following specifications: 4-rad dose at 1 m, 1-mm spot size, 50-ns pulse length, 2.25-MeV endpoint energy. The facility is located in an underground tunnel complex at the Nevada Test Site. Here subcritical experiments are performed to study the dynamic properties of plutonium. The Cygnus sources were developed as a primary diagnostic for these tests. Since subcritical tests are single-shot, high-value events -reliability and reproducibility are key issues. Enhanced reliability involves minimization of failure modes through design, inspection, and testing. Many unique hardware and operational features were incorporated into Cygnus to insure reliability. Enhanced reproducibility involves normalization of shot-to-shot output also through design, inspection and testing. The first SCE to utilize Cygnus, Armando, was executed on May 25, 2004. A year later, April -May 2005, calibrations using a plutonium step wedge were performed. The results from this series were used for more precise interpretation of the Armando data. In the period January -April 2007 Cygnus is fielded on Thermos, which is a series of several small-sample plutonium shots using a one-dimensional geometry. Pulsed power research generally dictates frequent change in hardware configuration. Conversely, subcritical applications have typically required constant machine settings. Therefore, while operating during the past three years we have accumulated a large database for evaluation of machine performance under highly consistent operating conditions. Through analysis of this database the reliability and reproducibility on Armando, Step Wedge, and Thermos will be presented.
  • Keywords
    plasma X-ray sources; plutonium; pulsed power technology; radiography; Armando; Cygnus Dial Beam Radiographic Facility; Nevada Test Site; Step Wedge; Thermos; hardware configuration; pulsed power research; radiographic sources; reliability; reproducibility; shot-to-shot output; small-sample plutonium shots; underground tunnel complex; Calibration; Data analysis; Geometry; Hardware; Inspection; Laboratories; Radiography; Reproducibility of results; Spatial databases; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
  • Conference_Location
    Albuquerque, NM
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4244-0915-0
  • Type

    conf

  • DOI
    10.1109/PPPS.2007.4345991
  • Filename
    4345991