Title :
Low temperature complex for dielectrometry measurements
Author :
Derkach, V.N. ; Golovashchenko, R.V. ; Goroshko, E.V. ; Korzh, V.G. ; Nedukh, S.V. ; Plevako, O.S. ; Tarapov, S.I.
Author_Institution :
Usikov Inst. of Radiophys. & Electron., NAS of Ukraine, Kharkov, Ukraine
Abstract :
Design and operating principles of experimental set-up for measuring superlow dielectric losses at temperatures 4.2-0.6 K are presented. The results of model experiments in a millimeter waveband at low temperatures are presented too. The set-up consists of the "top-loading" closed cycle evaporation refrigerator of 3He and the electrodynamical module. The module contains the sample under study which is shaped as open dielectric resonator on whispering gallery modes. The magnitude of losses is detected by analyzing both the width of resonant curve and the time of response of the resonator to the high-frequency pulse.
Keywords :
dielectric loss measurement; dielectric resonators; low-temperature techniques; millimetre wave measurement; 4.2 to 0.6 K; closed cycle evaporation refrigerator; cryogenic module; dielectrometry measurement; electrodynamical module; high-frequency pulse; low temperature complex; millimeter waveband; open dielectric resonator; operating principles; resonant curve width; superlow dielectric losses; time of response; top-loading refrigerator; whispering gallery modes; Dielectric loss measurement; Dielectric losses; Dielectric measurements; Helium; Loss measurement; Millimeter wave measurements; Refrigeration; Resonance; Temperature; Whispering gallery modes;
Conference_Titel :
Physics and Engineering of Microwaves, Millimeter, and Submillimeter Waves, 2004. MSMW 04. The Fifth International Kharkov Symposium on
Print_ISBN :
0-7803-8411-3
DOI :
10.1109/MSMW.2004.1346134