Title :
Hardware for precise in vivo pulse transmit time CNIBP tests
Author :
Peter, Lukas ; Cerny, Martin
Author_Institution :
Dept. of Cybern. & Biomed. Eng., VSB - Tech. Univ. of Ostrava, Ostrava, Czech Republic
fYear :
2013
Firstpage :
1
Lastpage :
4
Abstract :
Monitoring of changes in blood pressure is one the most commonly used medical methods. However as standard procedure it can only be done in discontinuous time intervals. It would be beneficial for diagnostic purposes if it was possible to monitor changes of blood pressure in continuous time intervals. Currently continuous measurement of blood pressure is only possible using invasive methods, which makes the measurement impractical for the doctors and uncomfortable for the patients. Physiologically there is connection between electrical and mechanical heart functions and blood pressure value. The article describes the method of measurement and ECG and PPG signal processing so as to obtain information about pulse wave transit related to value of blood pressure. This value is called pulse transit time - PTT. The measurement set up used for simultaneous receiving of all necessary biosignals and measurement software in LabView environment for signal processing of the acquired data are described here. This method can be a part of body sensor networks. Using this method will optimize the network device for capturing biosignals and current expansion monitored signals.
Keywords :
biomedical equipment; blood pressure measurement; body sensor networks; electrocardiography; medical signal detection; medical signal processing; patient monitoring; photoplethysmography; virtual instrumentation; ECG signal processing; LabView environment; PPG signal processing; blood pressure change monitoring; blood pressure value; body sensor network; continuous blood pressure measurement; current expansion monitored signal; diagnostic purpose; discontinuous time interval; electrical heart function; invasive method; measurement set up; measurement software; mechanical heart function; medical method; network device optimization; physiological; precise in vivo pulse transmit time CNIBP test hardware; pulse transit time; pulse wave transit; simultaneous necessary biosignal acquisition; Biomedical monitoring; Blood pressure; Electrocardiography; Finite impulse response filters; Pressure measurement; Sensors; Blood pressure; CNIBP; EKG; PPG; PTT;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Electronics (AE), 2013 International Conference on
Conference_Location :
Pilsen
ISSN :
1803-7232
Print_ISBN :
978-80-261-0166-6
Type :
conf
Filename :
6636514
Link To Document :
بازگشت