    Temperature measurement using Er doped SiO/sub 2/ glass

  • Author

    Aizawa, H. ; Takei, K. ; Katsumata, T. ; Komuro, S. ; Morikawa, T. ; Ogawa, S. ; Toba, E.

  • Author_Institution
    Sensor Photonics Res. Center, Toyo Univ., Saitama, Japan
  • Volume
    3
  • fYear
    2004
  • Firstpage
    2494
  • Abstract
    The temperature dependence of PL lifetime from an Er doped SiO/sub 2/ sensor with various concentrations have been evaluated in the temperature range 0/spl deg/C to 200/spl deg/C. An Er doped SiO/sub 2/ sensor with Er concentration above 5000 ppm and Al/Er=15 is considered to be suitable for the fiber-optic thermometer. The PL lifetimes of the Er doped SiO/sub 2/ sensor decrease from 10 ms to 8.6 ms at temperatures from 0/spl deg/C to 200/spl deg/C. An Er doped SiO/sub 2/ sensor is considered to be potentially useful for a fiber-optic fluorescence thermometer.
  • Keywords
    erbium; fibre optic sensors; fluorescence; optical glass; photoluminescence; radiative lifetimes; silicon compounds; spectral methods of temperature measurement; thermometers; 0 to 200 C; 8.6 ms; Er doped SiO/sub 2/ glass; Er doped SiO/sub 2/ sensor; Er doped fiber; SiO/sub 2/:Er,Al; fiber-optic fluorescence thermometer; photoluminescence lifetime; rare-earth metals; temperature dependence; temperature measurement;