  • Title

    A new configuration of electro-magnetic flowmeters with self-calibration-theoretical analysis

  • Author

    Honda, S. ; Yamamoto, T.

  • Author_Institution
    Keio Univ., Yokohama, Japan
  • Volume
    3
  • fYear
    2004
  • Firstpage
    2626
  • Abstract
    Electro-magnetic flowmeters have been one of the standard flowmeters to measure liquid flowrate in industry. This study proposes a new configuration consisting of two pairs of exciting magnetic coils and a pair of signal pickup electrodes with the higher driving frequencies than those of conventional electro-magnetic flowmeters. This rather complex configuration brings the meters a function of self-calibration and lowers the condition of the fluid conductivity for the measurement to such as pure distilled water. The theoretical analysis agrees well with experimental results and it clarifies the feasibility of the proposed configuration.
  • Keywords
    Maxwell equations; calibration; electromagnetic devices; flow measurement; flowmeters; electro-magnetic flowmeters; fluid conductivity; liquid flowrate; magnetic coils; signal pickup electrodes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE 2004 Annual Conference
  • Conference_Location
    Sapporo
  • Print_ISBN
    4-907764-22-7
  • Type

    conf

  • Filename
    1491894