DocumentCode
1631688
Title
Quick crack detection of the large vibrating screen lower beam based on combined technical method of MMMT and ET
Author
Xue Guanghui ; Zhao Guorui ; Zhu Shigang ; Liu Hui ; Wu Miao
Author_Institution
Sch. of Mech. Electron. & Inf. Eng., China Univ. of Min. & Technol., Beijing, China
fYear
2010
Firstpage
330
Lastpage
335
Abstract
The abrupt fracture of vibrating screen lower beam will make the whole coal preparation product line shutting down and result in large economic losses. In this paper, according to the difficulties and requirements of vibrating screen lower beam crack detection, a quick detection method was put forward based on combined technical method of metal magnetic memory testing and eddy current testing. The experimentation and spot application results showed that the method was efficient, and could achieved the early crack fault quick detection of vibrating screen lower beam. Its application could decrease even avoid the lower beam abrupt fracture occurrence of the vibrating screen, and bring enormous economic and social effects.
Keywords
assembling; beams (structures); coal; crack detection; eddy current testing; fracture; vibrations; abrupt fracture; coal preparation product line; crack fault quick detection; eddy current testing; metal magnetic memory testing; vibrating screen lower beam;
fLanguage
English
Publisher
ieee
Conference_Titel
Mechatronics and Embedded Systems and Applications (MESA), 2010 IEEE/ASME International Conference on
Conference_Location
Qingdao, ShanDong
Print_ISBN
978-1-4244-7101-0
Type
conf
DOI
10.1109/MESA.2010.5552045
Filename
5552045
Link To Document