DocumentCode :
163809
Title :
Packaging and reliability issues in microelectromechanical systems
Author :
Stanimirovic, I. ; Stanimirovic, Z.
Author_Institution :
IRITEL a.d. Beograd, Belgrade, Serbia
fYear :
2014
fDate :
12-14 May 2014
Firstpage :
333
Lastpage :
336
Abstract :
Packaging of microelectromechanical systems (MEMS) strongly affects the device performances. It is the core technology for the advancement of MEMS and is recognized as the next manufacturers challenge for the forthcoming years due to the growing market and stricter requirements. There is a vast diversity of applications and the most of MEMS packaging challenges are application dependent. It is the objective of this paper to review and discuss the most common MEMS packaging challenges. For that reason, five case studies on MEMS pressure sensors, MEMS accelerometers, RF MEMS, MOEMS and BioMEMS are presented for an in-depth illustration.
Keywords :
accelerometers; bioMEMS; electronics packaging; integrated circuit reliability; micro-optomechanical devices; microsensors; pressure sensors; MEMS accelerometers; MEMS packaging; MEMS pressure sensors; MOEMS; RF MEMS; bioMEMS; core technology; microelectromechanical systems; reliability; Materials; Micromechanical devices; Packaging; Radio frequency; Reliability; Temperature sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microelectronics Proceedings - MIEL 2014, 2014 29th International Conference on
Conference_Location :
Belgrade
Print_ISBN :
978-1-4799-5295-3
Type :
conf
DOI :
10.1109/MIEL.2014.6842157
Filename :
6842157