• DocumentCode
    1638985
  • Title

    Continuous operation performance of faulty induction motor drives

  • Author

    Mendes, A.M.S. ; Cardoso, A. J Marques

  • Author_Institution
    Dept. de Engenharia Electrotecnica e de Computadores, Coimbra Univ., Portugal
  • Volume
    1
  • fYear
    2003
  • Firstpage
    547
  • Abstract
    This paper presents a study regarding the continuous operation performance of a faulty three-phase induction motor fed by a direct torque controlled voltage source inverter. Several remedial operating strategies are compared in order to analyze which of them better fit into a post-fault drive reconfiguration strategy. This analysis comprises input motor line current distortion and efficiency. Electromagnetic torque harmonics are also taken into account.
  • Keywords
    distortion; electrical faults; harmonic analysis; induction motor drives; invertors; machine control; torque control; continuous operation performance; direct torque controlled voltage source inverter; efficiency; electromagnetic torque harmonics; faulty induction motor drives; input motor line current distortion; post-fault drive reconfiguration strategy; remedial operating strategies; three-phase induction motor; Induction motor drives; Induction motors; Inverters; Leg; Power harmonic filters; Rotors; Stator windings; Topology; Torque; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International
  • Print_ISBN
    0-7803-7817-2
  • Type

    conf

  • DOI
    10.1109/IEMDC.2003.1211316
  • Filename
    1211316