• DocumentCode
    1641186
  • Title

    Limited angle tomography via multiresolution analysis and oversampling

  • Author

    Olson, Tim

  • Author_Institution
    Dept. of Math., Dartmouth Coll., Hanover, NH, USA
  • fYear
    1992
  • Firstpage
    215
  • Lastpage
    218
  • Abstract
    A method is presented for reconstructing a function from its line integrals. This problem arises in imaging whenever the physical constraints of the system prohibit the gathering of the line integrals over the angles -π/2<θ<0. The first portion of the algorithm decomposes the limited angle operator L into a tensor product structure that allows an efficient calculation of its singular value decomposition. The second portion of the algorithm uses multiresolution analysis in order to mollify the problem, which is known to be extremely ill conditioned. It is thought that these methods may lead to a more stable algorithm for limited angle reconstruction
  • Keywords
    computerised tomography; image reconstruction; medical image processing; algorithm; imaging; limited angle operator; limited angle reconstruction; line integrals; multiresolution analysis; oversampling; singular value decomposition; tensor product structure; tomography; Educational institutions; Electrons; Fourier transforms; Image reconstruction; Mathematics; Medical diagnosis; Multiresolution analysis; Singular value decomposition; Tensile stress; Tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Time-Frequency and Time-Scale Analysis, 1992., Proceedings of the IEEE-SP International Symposium
  • Conference_Location
    Victoria, BC
  • Print_ISBN
    0-7803-0805-0
  • Type

    conf

  • DOI
    10.1109/TFTSA.1992.274199
  • Filename
    274199