• DocumentCode
    1641290
  • Title

    The measurement uncertainty of electromagnetic conducted immunity test using CDN

  • Author

    Mun, Jun-Chul ; Lim, Young-Chae ; Kim, Yung-Kyu

  • Author_Institution
    Minist. of Inf. & Commun. of Radio Res. Lab
  • Volume
    1
  • fYear
    2005
  • Firstpage
    650
  • Abstract
    We estimated the measurement uncertainty of electromagnetic conducted immunity using CDN (coupling/decoupling network). We analyzed the contribution factors for the uncertainty and obtained the uncertainty by each factor. The contributions of the uncertainty are the repeatability of measurement system; harmonics of power amplifier; the accuracy of power meter; mismatch between power amplifier and CDN; and mismatch between power meter and QDN. We obtained that the expanded uncertainty is 1.17 dB in level of confidence and plusmn 0.43 V of error range in 3 V. These results could tell that the most important uncertainty contribution is mismatched between measurement system in electromagnetic conducted immunity test. Therefore, we know that it is important to match impedance on electromagnetic conducted immunity test
  • Keywords
    electromagnetic compatibility; immunity testing; measurement uncertainty; coupling-decoupling network; electromagnetic conducted immunity test; measurement uncertainty; Cables; Electromagnetic coupling; Electromagnetic radiation; Frequency; Impedance; Measurement uncertainty; Medical services; Power amplifiers; Radiofrequency amplifiers; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications, 2005. MAPE 2005. IEEE International Symposium on
  • Conference_Location
    Beijing
  • Print_ISBN
    0-7803-9128-4
  • Type

    conf

  • DOI
    10.1109/MAPE.2005.1617994
  • Filename