Abstract :
A FLIR SC5000 IR thermovision camera was used for analyzing the temperature distribution on the gold surface of the test devices (Schottky diode). The goal was to estimate the values of the temperature in various areas on the surface of the test device. In order to increase the emissivity, the surface was covered with a spray paint, a solution allowing to obtaining better estimations of the surface temperature.
Keywords :
Schottky diodes; cameras; infrared imaging; spraying; surface topography measurement; temperature distribution; temperature measurement; FUIR SC5000 IR thermovision camera; Schottky diode; gold surface; spray paint; surface temperature estimation; temperature distribution; thermographic analysis; Cameras; Estimation; Gold; Paints; Surface treatment; Temperature distribution; Temperature measurement; IR thermography; Schottky diode; emissivity; surface temperature;