In this work, a novel hybrid system able to provide focused microwave radiometric temperature and/or conductivity measurements and hyperthermia treatment via microwave irradiation is experimentally tested. The main module of the system is an ellipsoidal cavity, which provides the appropriate focusing of the electromagnetic energy on the area of interest. The system has been used the past few years in experiments with different configuration setups including phantom, animal and human volunteer measurements yielding promising outcome. New aspects of our research are presented in this paper regarding both radiometry and hyperthermia modules. On one hand, it is examined whether the system is capable of sensing real time progressive local variations of temperature and/or conductivity in customized phantom setups; on the other, the focusing attributes of the system are explored for different positions and types of phantoms used for hyperthermia. The results show that the system is able to detect local concentrated gradual temperature and conductivity variations expressed as an increase of the output radiometric voltage. When contactless focused hyperthermia is performed, the results show significant temperature increase at specific phantom areas. In this case, the effect of a dielectric matching layer placed around the phantoms has been also tested resulting in the enhancement of the energy penetration depth.
Keywords :
biomedical measurement; hyperthermia; microwave measurement; patient diagnosis; phantoms; radiation therapy; conductivity measurement; dielectric matching layer effects; electromagnetic energy focusing; head tissue phantom; hyperthermia treatment; microwave radiometric measurements; noninvasive microwave irradiation; passive focused monitoring; temperature measurement; Animals; Conductivity measurement; Humans; Hyperthermia; Imaging phantoms; Microwave frequencies; Microwave radiometry; Monitoring; System testing; Temperature sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
BioInformatics and BioEngineering, 2008. BIBE 2008. 8th IEEE International Conference on
Conference_Location :
Athens
Print_ISBN :
978-1-4244-2844-1
Electronic_ISBN :
978-1-4244-2845-8
Type :
conf
DOI :
10.1109/BIBE.2008.4696770
Filename :
4696770
Link To Document :
بازگشت