Title :
Study of partial discharge occurrence patterns for construction of degradation diagnosis system
Author :
Komori, F. ; Hikita, M. ; Suzuoki, Y. ; Mizutani, T.
Author_Institution :
Toba Nat. Coll., Japan
Abstract :
The authors have constructed a prototype of partial discharge (PD) pulse measurement and degradation diagnosis system (PDMES-I). PDMES-I consists of PD measurement system, PD pulse data analyzing system and degradation system. The PD patterns (φ-q-n distribution) of low density polyethylene (LDPE) and polyimide (PI) have been measured for CIGRE METHOD-II electrode system. On the basis of the experimental results, a model for a PD occurrence pattern of a half cycle is proposed. We have made an artificial PD pattern by computer simulation on the basis of the model. Finally, we have applied the artificial PD patterns to the actual patterns to determine the degree of in the Insulator-Gap-Insulator (glass) electrode system
Keywords :
insulation testing; partial discharges; polyethylene insulation; polymer films; CIGRE METHOD-II electrode; Insulator-Gap-Insulator electrode; LDPE; PDMES-I; computer simulation; data analysis; degradation diagnosis system; partial discharge occurrence pattern; polyimide; pulse measurement; Data analysis; Degradation; Density measurement; Electrodes; Partial discharge measurement; Partial discharges; Polyethylene; Polyimides; Prototypes; Pulse measurements;
Conference_Titel :
Properties and Applications of Dielectric Materials, 1997., Proceedings of the 5th International Conference on
Conference_Location :
Seoul
Print_ISBN :
0-7803-2651-2
DOI :
10.1109/ICPADM.1997.617568