DocumentCode
1644789
Title
A High Speed Pulse Detector at W-Band
Author
Changfei Yao ; Wang, Ling ; Tang, Xiaohong ; Mao, Ruijie
Author_Institution
State Key Lab. of Millimeter Waves, Southeast Univ., Nanjing
fYear
2008
Firstpage
83
Lastpage
86
Abstract
A high speed pulse detector at W-band is analyzed and designed based on hybrid integrated technology. The beam lead detector diode HSCH-9161 is adopted. The tested results show that the rising time of the output pulse within 92~98GHz is less than 2~3ns after the modulator and detector when the input modulating pulse signal rise time is 700ps. Due to its fast response speed, this detector can be applied in a variety of W- band pulse detecting systems.
Keywords
high-speed techniques; microwave detectors; millimetre wave detectors; W-band; beam lead detector diode; high speed pulse detector; hybrid integrated technology; Bandwidth; Detectors; Diodes; Microstrip; Millimeter wave technology; Probes; Pulse measurements; Pulse modulation; Space vector pulse width modulation; Waveguide transitions;
fLanguage
English
Publisher
ieee
Conference_Titel
Millimeter Waves, 2008. GSMM 2008. Global Symposium on
Conference_Location
Nanjing
Print_ISBN
978-1-4244-1885-5
Electronic_ISBN
978-1-4244-1886-2
Type
conf
DOI
10.1109/GSMM.2008.4534564
Filename
4534564
Link To Document