• DocumentCode
    1646132
  • Title

    A study on detection of defects in cable splice by analysis of ultrasonic signal

  • Author

    Park, Chi-Young ; Kwak, Hee-Ro ; Song, II-Keun ; Kim, Sang-Jun

  • Author_Institution
    Soong-sil Univ., Seoul, South Korea
  • Volume
    1
  • fYear
    1997
  • Firstpage
    315
  • Abstract
    This paper describes a diagnostic technique of cable splice by detection of ultrasonic signal. For simulating the ultrasonic signal by partial discharge, an ultrasonic generator was inserted in cable splice. Internal defects were purposely made by needle electrode and ring shape electrode in cable splice. It was shown that defects in cable splice can be detected and the position of defects would be found out by ultrasonic signal measurement
  • Keywords
    cable jointing; insulation testing; partial discharges; power cable insulation; power cable testing; power cables; ultrasonic materials testing; cable splice; defect detection; needle electrode; partial discharge; ring electrode; ultrasonic signal measurement; Detectors; Electrodes; Needles; Partial discharge measurement; Power cable insulation; Power cables; Signal analysis; Signal generators; Surface discharges; Ultrasonic variables measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 1997., Proceedings of the 5th International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    0-7803-2651-2
  • Type

    conf

  • DOI
    10.1109/ICPADM.1997.617591
  • Filename
    617591