Abstract
The boost rectifier, when operated in discontinuous conduction mode and constant duty ratio, has a power factor less than unity, which approaches unity at the expense of high conversion ratios. The proposed control scheme corrects this problem by providing unity power factor, even for low conversion ratios, in an open loop fashion at constant switching frequency.
Keywords
AC-DC power convertors; DC-DC power convertors; power factor correction; rectifying circuits; switching circuits; voltage control; boost rectifier; constant duty ratio; constant switching frequency; conversion ratio; discontinuous conduction mode; open loop control scheme; unity power factor; Circuits; Current control; DC-DC power converters; Feedback loop; Open loop systems; Power electronics; Pulse width modulation; Reactive power; Rectifiers; Voltage;