DocumentCode :
1649934
Title :
Estimation of the capacity of nickel-cadmium batteries by measuring impedance using electrolyte-deficient battery characteristics
Author :
Kato, Naoki ; Yamamoto, Katsuhiko
Author_Institution :
NTT Interdisciplinary Res. Lab., Tokyo, Japan
fYear :
1995
Firstpage :
772
Lastpage :
777
Abstract :
This paper describes a method of testing trickle-charged nickel-cadmium (Ni-Cd) batteries. The main causes of deterioration are shown to be short-circuit and electrolyte leakage. In the former case, the batteries are easily tested by measuring the voltage. In the latter case, the authors show that measuring the impedance is an effective way to test the condition of batteries because its logarithm is linearly related to the capacity, and this relationship can be obtained easily and quickly from characteristics of electrolyte-deficient batteries
Keywords :
battery testers; cadmium; electric impedance measurement; electrochemistry; electrolytes; nickel; secondary cells; Ni-Cd; battery capacity; deterioration; electrolyte leakage; electrolyte-deficient battery characteristics; impedance measurements; secondary battery testing; short-circuit; trickle-charged; Battery charge measurement; Circuit testing; Current measurement; Electrodes; Impedance measurement; Laboratories; Power measurement; System testing; Time measurement; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Telecommunications Energy Conference, 1995. INTELEC '95., 17th International
Conference_Location :
The Hague
Print_ISBN :
0-7803-2750-0
Type :
conf
DOI :
10.1109/INTLEC.1995.499046
Filename :
499046