DocumentCode :
1653151
Title :
Evaluation of LF AC-DC difference of coaxially mounted thermal voltage converter
Author :
Filipski, P.S. ; Clark, R.F. ; Paulusse, D.C.
Author_Institution :
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
Volume :
1
fYear :
1997
Firstpage :
720
Abstract :
The paper describes the mathematical model of a coaxially mounted thermal voltage converter. Results of simulations are compared with results of experiments conducted in the 1 kHz-1000 kHz frequency range
Keywords :
calibration; measurement standards; voltage measurement; 1 to 1000 kHz; LF AC-DC difference; calibration; coaxially mounted thermal voltage converter; mathematical model; simulations; transfer standards; Analog-digital conversion; Coaxial components; Conductors; Connectors; Councils; Frequency conversion; Inductance; Testing; Uncertainty; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 1997. IMTC/97. Proceedings. Sensing, Processing, Networking., IEEE
Conference_Location :
Ottawa, Ont.
ISSN :
1091-5281
Print_ISBN :
0-7803-3747-6
Type :
conf
DOI :
10.1109/IMTC.1997.604047
Filename :
604047
Link To Document :
بازگشت