Abstract :
Window-temperature measurements on a double-disc sapphire window have been performed during a series of high-power, long-pulse tests of a 110 GHz, internal-converter gyrotron using a 10-μm, infrared camera. Details of the infrared-imaging setup will be discussed and the results obtained will be presented. From these measurements, loss-tangent and film-coefficient values used in calculations can be verified
Keywords :
electron tube components; electron tube testing; gyrotrons; infrared imaging; temperature measurement; 10 micron; 110 GHz; double-disc sapphire window; film-coefficient; high-power gyrotron; infrared camera; infrared-imaging; internal quasi-optical converter; long-pulse tests; loss-tangent; window-temperature measurements; Cameras; Coolants; Cooling; Gyrotrons; Mirrors; Peak to average power ratio; Power distribution; Radio frequency; Temperature measurement; Testing;