DocumentCode
1654428
Title
Application of Optimization with Scaled Conjugate Gradient Algorithm in IMRT
Author
Wang Zhuoyu ; Zhou Linghong ; Chen Chaomin ; Lu Wenting ; Zeng Xin ; Zhu Lin
Author_Institution
Sch. of Biomed. Eng., Southern Med. Univ., Guangzhou
fYear
2008
Firstpage
751
Lastpage
754
Abstract
Objective To implement the optimization of beam weight in IMRT planning optimization. Methods The treatment planning system of IMRT has been developed with SCG algorithm for determining the intensity-modulated beams and pencil beam model for dose distribution. Results A example of a lung case has been optimized by the IMRT system. The DVH shows that 97%PTV is irradiated by 95%~105% of the described dose. OAR and normal tissue are irradiated by no more than 15% and 40% respectively. Conclusion SCG algorithm implemented as an inverse planning algorithm for determining the intensity-modulated beams that will most closely generate a desired dose distribution is presented as well as a method for dose calculation in IMRT using pencil beam model.
Keywords
dosimetry; lung; optimisation; radiation therapy; IMRT treatment planning optimization; IMRT treatment planning system; SCG algorithm; beam weight optimization; dose distribution; intensity modulated beams; intensity modulated radiation therapy; inverse planning algorithm; lung; pencil beam model; scaled conjugate gradient algorithm; Biomedical engineering; Chaos; Convolution; Cost function; Current distribution; Gradient methods; Iterative algorithms; Kernel; Lungs; Neoplasms;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on
Conference_Location
Shanghai
Print_ISBN
978-1-4244-1747-6
Electronic_ISBN
978-1-4244-1748-3
Type
conf
DOI
10.1109/ICBBE.2008.183
Filename
4535063
Link To Document