This paper presents a new method for automatic common carotid artery detection in B-mode ultrasonography. The proposed method is based on the location of phase symmetry patterns at apropriate scale of analysis. The local phase information is derived from the monogenic signal and isotropic log-normal band-pass filters, and the resulting common carotid artery is located using a dynamic programming optimization algorithm. The experiments show that the proposed method is more robust to noise than previous approaches, although additional research is required for robust common carotid artery detection on the more complicated cases.
Keywords
band-pass filters; biomedical ultrasonics; dynamic programming; log normal distribution; medical image processing; optimisation; B-mode ultrasonography; B-mode ultrasound images; automatic common carotid artery detection; dynamic programming optimization; isotropic log-normal band-pass filters; local phase information; local phase symmetry; monogenic signal; robust common carotid artery lumen detection; Carotid arteries; Image segmentation; Noise; Robustness; Speckle; Ultrasonic imaging; biomedical image processing; carotid artery detection; dynamic programming; monogenic signal; ultrasonography;
fLanguage
English
Publisher
ieee
Conference_Titel
Acoustics, Speech and Signal Processing (ICASSP), 2013 IEEE International Conference on
Conference_Location
Vancouver, BC
ISSN
1520-6149
Type
conf
DOI
10.1109/ICASSP.2013.6637785
Filename
6637785
Link To Document