DocumentCode
1657668
Title
A high-T, high-resolution thermometer based on a microfiber coupler tip
Author
Ding, Ming ; Wang, Pengfei ; Brambilla, Gilberto
Author_Institution
Optoelectron. Res. Centre, Univ. of Southampton, Southampton, UK
fYear
2012
Firstpage
1
Lastpage
2
Abstract
A compact thermometer based on a broadband microfiber coupler tip is demonstrated in this paper. The thermometer can measure a broad temperature range from room temperature to 1283°C. This is the highest temperature measured with a silica optical fiber device. An average sensitivity of 11.96pm/°C was achieved for a coupler tip diameter of ~3 μm.
Keywords
fibre optic sensors; optical fibre couplers; thermometers; broadband microfiber coupler tip; high resolution thermometer; silica optical fiber device; size 3 mum; temperature 1283 degC; Couplers; Optical fiber couplers; Optical fiber sensors; Spatial resolution; Temperature measurement; Temperature sensors;