The experimental study of a cyclotron-resonance maser (CRM) in a 2D periodic-waveguide is reported. Using a low-energy electron beam (~5 keV, 0.1 A), the experiment is operated in microwave-frequency around 7 GHz in an axial magnetic field (~3 kG). The corresponding efficiency is ~10%. This experiment is a first stage in the development of a new CRM-array concept
Keywords
cyclotron masers; microwave measurement; rectangular waveguides; 0.1 A; 2D periodic waveguide; 5 keV; 7 GHz; axial magnetic field; cyclotron maser experiment; cyclotron resonance maser array; efficiency; experimental study; loaded waveguides; low energy electron beam; microwave frequency; rectangular waveguide; Cyclotrons; Electron beams; Magnetic field measurement; Magnetic fields; Masers; Oscilloscopes; Pulsed power supplies; Radio frequency; Solenoids; Voltage;