DocumentCode
1658191
Title
A Study of Suburban Energy Balance of Beijing City in Summertime
Author
Dou Junxia ; Liu Weidong
Author_Institution
Inst. of Urban Meteorol. China Meteorol. Adm. Beijing, Beijing
fYear
2008
Firstpage
4723
Lastpage
4725
Abstract
The suburban energy partitioning was examined by using the data collected in Beijing city during the period from July to August in 2007. The results show that daily mean values of net radiation, latent heat flux and sensible heat flux for all the measurement days was 111.3 W/m2, 65.7 W/m2 and 22.9 W/m2, respectively. Meanwhile, daily mean values of net radiation, latent heat flux and sensible heat flux for clear days was 161.1 W/m2, 80.6 W/m2 and 36.7 W/m2 respectively. Energy partitioning was dominated by latent heat flux under both clear and all sky conditions, the mean diurnal Bowen ratio values was 0.67 and 0.54.
Keywords
atmospheric radiation; atmospheric techniques; atmospheric temperature; AD 2007 07 to 08; Beijing city; latent heat flux; mean diurnal Bowen ratio; net radiation; sensible heat flux; suburban energy balance; suburban energy partitioning; summertime; Cities and towns; Humidity; Land surface temperature; Meteorology; Poles and towers; Sensor systems; Temperature sensors; Velocity measurement; Water heating; Wind speed;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on
Conference_Location
Shanghai
Print_ISBN
978-1-4244-1747-6
Electronic_ISBN
978-1-4244-1748-3
Type
conf
DOI
10.1109/ICBBE.2008.338
Filename
4535218
Link To Document