• DocumentCode
    165832
  • Title

    Safe and efficient wind power for urban area

  • Author

    Verdum, Valdirene ; Petry Homrich, Roberto

  • Author_Institution
    Fed. Univ. of Rio Grande do Sul, Porto Alegre, Brazil
  • fYear
    2014
  • fDate
    25-27 March 2014
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The paper outlines a wind turbine coupled to a permanent magnets synchronous generator (PMSG). The PMSG is not located in the horizontal axis of the turbine, but in the blades´ tip instead. The basic magnetic topology is constituted by sixty magnets mounted on the surface of the rotor and a conventional stator winding. This wind generator is coupled to a shroud that can increase power output and is a safety factor to protect installations, equipment and people. So the system is compounded by a horizontal axis wind turbine, a PMSG and a shroud. These three main parts were designed to be operated in urban areas. Therefore, the priority is efficiency and safety.
  • Keywords
    permanent magnet generators; rotors; stators; synchronous generators; wind power; wind turbines; PMSG; magnetic topology; permanent magnets synchronous generator; rotor; stator winding; urban area; wind generator; wind power; wind turbine; Air gaps; Blades; Magnetic circuits; Magnetic flux; Rotors; Wind power generation; Wind turbines; finite element analysis; magnets-mounted topology; permanent magnet synchronous machines; wind power;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ecological Vehicles and Renewable Energies (EVER), 2014 Ninth International Conference on
  • Conference_Location
    Monte-Carlo
  • Print_ISBN
    978-1-4799-3786-8
  • Type

    conf

  • DOI
    10.1109/EVER.2014.6844145
  • Filename
    6844145