• DocumentCode
    165892
  • Title

    An interactive GUI tool for thyroid Uptake studies using Gamma Camera

  • Author

    Vignesh, T. Sai ; Subramaniyan, V. Siva ; Rajamani, Kumar T. ; Siva Sankara Sai, S.

  • Author_Institution
    Dept. of Phys., Sri Sathya Sai Inst. of Higher Learning, Prasanthi Nilayam, India
  • fYear
    2014
  • fDate
    24-27 Sept. 2014
  • Firstpage
    305
  • Lastpage
    309
  • Abstract
    Thyroid uptake study is a technique that requires injection of a radio-isotope/radiotracer emitting gamma rays into the blood stream of the patient. Thyroid imaging is done by means of Thyroid Uptake imaging system. In the absence of a sophisticated system, imaging can also be done using Gamma Camera. By intravenously injecting 2 millicuries of Technetium-99m pertechnetate radio-isotope, serial thyroid images are acquired. This Uptake study provides Functional information and is useful for diagnosis and treatment of Hyperthyroidism. Thyroid uptake study done using Gamma Camera has to be calibrated at each laboratory using this technique. In our hospital it has been standardized that a tracer uptake of greater than 2% is considered Hyperthyroidism, between 0.5 and 2% is considered normal and less than 0.5% is considered Hypothyroidism. Thyroid Uptake is calculated based on the counts. Counts are nothing but the sum of all intensities in the selected region of the image. Gamma Camera uses a LEAP (Low Energy All Purpose) collimator which handles only photons emitted from radioi-sotopes having lower emission energies. So Technetium-99m is used which has its energy of emission around 140 keV. For a typical Thyroid Uptake Probe where Iodine-131 having greater emission energy of 364 keV is preferred, existing Thyroid Uptake software cannot be used. Therefore an Interactive GUI (Graphical User Interface) tool was developed for thyroid Uptake studies using Fiji for determination of tracer uptake by manually drawing the ROI (Region of Interest) around left and right thyroid lobes separately. Developed tool was tested on 30 real time thyroid cases (26 female and 4 male) and the uptake values obtained are compared with those obtained from the existing software tool.
  • Keywords
    bioinformatics; blood; diseases; gamma-rays; graphical user interfaces; medical computing; patient diagnosis; patient treatment; LEAP; ROI; functional information; gamma camera; graphical user interface; hyperthyroidism diagnosis; hyperthyroidism treatment; interactive GUI tool; low energy all purpose collimator; patient blood stream; region of interest; thyroid uptake; tracer uptake determination; Biomedical imaging; Cameras; Graphical user interfaces; Nuclear medicine; Software; Standards; Anticubital; Fiji; Interactive GUI; ROI; Radiotracer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advances in Computing, Communications and Informatics (ICACCI, 2014 International Conference on
  • Conference_Location
    New Delhi
  • Print_ISBN
    978-1-4799-3078-4
  • Type

    conf

  • DOI
    10.1109/ICACCI.2014.6968210
  • Filename
    6968210