DocumentCode :
1663594
Title :
Voltage Sag Ride-Through of Super High-Speed Turbo Compressor
Author :
Yim, Jung-Sik ; Sul, Seung-Ki ; Byeon, Ji-Seop ; Lim, Sung-Il
fYear :
2007
Firstpage :
656
Lastpage :
660
Abstract :
Turbo compressors have been extensively used in the factory automation as a part of pneumatic manipulators. Authors developed a position sensorless super-high speed turbo compressor, and it has been installed and working at the industrial plants for years. But repeated failures have been reported at some specific sites. In this paper, the repeated failures are analyzed through experiments and theoretical approach and the remedy against the failures is proposed. Through the analysis, it is presented that there are current overshoots at the instances of voltage sags due to the time delay of dc-link voltage measurement, and the overshoots sometimes trip the inverter even after the voltage sags are cleared. And, the measurement circuit has been modified to reduce time delay. The proposed method has been applied to the failure sites, and the repeated failures have been disappeared.
Keywords :
compressors; failure analysis; industrial plants; invertors; power supply quality; turbomachinery; DC-link voltage measurement; high-speed turbo compressors; measurement circuit; repeated failures analysis; time delay; voltage sag; Delay effects; Failure analysis; Industrial plants; Inverters; Manufacturing automation; Power quality; Power system stability; Time measurement; Voltage fluctuations; Voltage measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 2007. 42nd IAS Annual Meeting. Conference Record of the 2007 IEEE
Conference_Location :
New Orleans, LA
ISSN :
0197-2618
Print_ISBN :
978-1-4244-1259-4
Electronic_ISBN :
0197-2618
Type :
conf
DOI :
10.1109/07IAS.2007.104
Filename :
4347853